PT. Beton Elemenindo Perkasa
Call us: 022-6866031
  • Home
  • Company Profile
    • Vision & Mission
    • History
    • Direction to Factory
    • Download Our Catalog
    • Watch Video
  • Product
    • Hollow Core Slab
      • HCS Home
      • Installation
      • Shipping
      • Placing
        • Placing on Concrete Structure
        • Placing on Steel Structure
        • Placing on Concrete Formwork
      • Load Capacity
      • HCS Details
    • Half Slab
      • Placing
    • Pile
      • 20 x 20 4D10 & 4D13
      • 25 x 25 4D13 & 4D16
      • 28 x 28 3D13
      • 32 x 32 3D16
      • 30 x 30
      • 35 x 35
      • 40 x 40
      • Drop Hammer
      • Hydraulic Jacked Pilling
    • Facade
      • Installation
      • Shipping
      • b-facade
    • Precast Concrete Fence
      • Precast Concrete Fence Motif
      • Installation
      • Dimension
      • H-Beam
    • Precast Concrete Pipe
    • Ecolite Panel
    • Hollow Core Wall
      • Details
    • Kansteen
      • Kansteen Hollow
      • Kansteen Type K-A
      • Kansteen Type K-A1
      • Kansteen Type K-B
      • Kansteen Type K-C
      • Kansteen Type K – 03
      • Kansteen Type K – 04
    • BEPMIX
    • Prefabricated Bathroom
    • U Ditch Precast
      • U-Ditch West Java
        • U-Ditch West Java Standard Small Dry Cast
        • U-Ditch West Java Standard Small Wet Cast
        • U-Ditch West Java Standard Large Wet Cast
        • Cover U-Ditch West Java Small Light Duty & Heavy Duty
        • Cover U-Ditch West Java Standard Large Light Duty & Heavy Duty
      • U-Ditch East Java
        • U-Ditch East Java Standard Small Wet Cast
        • U-Ditch East Java Standard Large Gandar 5 ton & 10 ton
        • Cover U-Ditch East Java Small Gandar 5 ton & 10 ton
        • Cover U-Ditch East Java Large Gandar 5 ton & 10 ton
    • Precast Stair
      • Step Stair
    • Box Culvert
      • Box Culvert Light Duty
      • Box Culvert Heavy Duty
    • Special Product
      • BEP Well
      • Tile Difable
      • Gutter
      • Barrier
      • Precast Table
      • Flower Case
      • Precast Chair
      • Bench Precast
      • Car Stopper
      • T – Beam
      • Beam & Coloum Precast
  • Project
    • On Going Project
    • Finished Project
  • News
  • Job Opportunity
    • Job Description
  • Contact Us
  • Bahasa Indonesia
  • English
Search the site...
Home» Products » Pile » 25 x 25

25 x 25

DATA

Triangle Pile, side length: 25 cm
Concrete Quality: K-450
Dimension & Main Reinforcement: 4D13mm or 4D16mm
Stirrup: ø 5 mm (tolerance 0.2 mm)
Area of Steel: 8.04 cm²
Area of concrete (netto): 617.00 cm²

CALCULATION

Strees allowable of Concrete Compression: 168.08 Kg/cm²
Strees allowable of Steel Tension: 2.262 Kg/ cm²

P AXIAL Ultimate :

P = 121.885 Kg = 121.9 Ton
SAFETY FACTOR : 2.1
P allowable : 40 TON for 4D13mm or 45 TON for 4D16mm

Notes :

1. P allowable Concrete = 0.45 fc’ = 0.45 x (0.83 x 450)

2. Minimum age of pile > 28 day

Back to Pile

Head Office / Factory

  • +6222-686 6031
  • +6222-686 6033 (FAX)
  • marketing@beton.co.id

Address

Jl. Raya Batujajar Km. 5 No. 56 Desa Giri Asih, Cangkorah – Batujajar Bandung – 40561

PASURUAN FACTORY
Dusun Pacinan RT. 005 RW. 005
Jl. Raya Nguling, Sedarum
Kab. Pasuruan Jawa Timur
0343 – 450 8872
0343 – 450 8867

Jakarta Office

  • +6221-5890 5200
  • +6221-2944 9895 (FAX)
  • marketing@beton.co.id

Address

Bussiness Park Kebon Jeruk Unit E1-18 Jl. Meruya Ilir Raya No.88
Jakarta Barat 11620

SURABAYA OFFICE
Jl. Pattimura, Kompleks Ruko Plaza Segi 8 Blok C-829
Surabaya, Jawa Timur

BEP Company Profile Video

© 2020 PT. Beton Elemenindo Perkasa | www.beton.co.id
  • Home
  • Company Profile
  • Product
  • Project
  • News
  • Job Opportunity
  • Contact Us
  • Bahasa Indonesia
  • English